Spare Parts Wizard
  • Home
  • Furnace Parts
    • Goodman, GMC, Janitrol, Amana >
      • GMPN040-3
      • GMPN060-3
  • Parts By Type
    • Blower Motors >
      • B1340020
      • B1340021
      • B1340022
    • Capacitors >
      • CAP125000370CP
    • Flame Sensors >
      • B1172606
    • Gas Valves >
      • B1282614
    • Hot Surface Ignitors >
      • B1401018
    • Inducer Motors >
      • B2833001
    • Safety Switches >
      • 1370906
      • B1370253
      • B1370154
      • B1370820
      • 1370908
      • 1370910
  • Home
  • Furnace Parts
    • Goodman, GMC, Janitrol, Amana >
      • GMPN040-3
      • GMPN060-3
  • Parts By Type
    • Blower Motors >
      • B1340020
      • B1340021
      • B1340022
    • Capacitors >
      • CAP125000370CP
    • Flame Sensors >
      • B1172606
    • Gas Valves >
      • B1282614
    • Hot Surface Ignitors >
      • B1401018
    • Inducer Motors >
      • B2833001
    • Safety Switches >
      • 1370906
      • B1370253
      • B1370154
      • B1370820
      • 1370908
      • 1370910
Search by typing & pressing enter

Goodman GMPN060-3 Parts, GMC, Janitrol, Amana

​Locate Goodman GMPN0603 (GMC, Janitrol, Amana) parts here. View diagrams, breakdowns and parts list. Also, view manuals, installation guides and error codes list. The manual contains important information regarding your safety. It should be read before servicing any part of your furnace. 

Most Common GMPN060-3 Replacement Parts

  1. Vent Motor – B2833001
  2. Pressure Switch -B1370148
  3. Primary Limit Switch 160 Degrees – 1370908
  4. White Rogers Gas Valve H.S.I. – B1282614
  5. Hot Surface Ignitor (HSI)- B1401018
  6. Flame Sensor – B1172606
  7. HSI Board w/ 9 Pin Connector – B1809913 (Ebay)
  8. Direct Drive Blower Motor 1/3 HP – B1340021
On This Page

Cabinet Parts List & Diagram

Heat Exchanger Parts List & Diagram

Burner Box Parts List & Diagram

Control Panel Parts List & Diagram

Blower Assembly Parts List & Diagram

Air Filters & Accessories

Service Manuals

Troubleshooting Tips & Videos


Goodman GMPN060-3 Cabinet Replacement Parts List

Goodman GMPN060-3 Cabinet Replacement Parts List
Diagram Item # Part Description / # Where To Buy
11 Cabinet Wrapper 2816512P * N/A
21 Top Panel Downflow 14″ - 2558504 * N/A
31 Control Access Door 17.5″ - 2812007P Ebay
41 O Ring 2.25 x .156 - B2832606 Ebay
51 Flue Restrictor Plate 1.252 Diameter - B2864903 * N/A
61 Vent Motor - B2833001 Amazon
71 Blower Access Door 14″ - 0221F00031PBB Ebay
81 Door Strike 1PC -B1392148 Amazon
91 Door Catch 1PC -B1392146 * N/A
101 Blower Door View Port Bushing - B1392139 * N/A
111 Vent Pressure Switch - B1370148 Amazon
121 J-Box - 2514501 * N/A
131 J-Box Cover - 2515501 * N/A
NS Duct Angle 14″ 2524000 * N/A
NS Door Switch B1370820 Sears Parts Direct
NS Pressure Switch Hose B1392705 Sears Parts Direct
NS = Not Shown
* = Obsolete

Goodman GMPN060-3 Heat Exchanger Replacement Parts List

<h3>Goodman GMPN060-3 Heat Exchanger Replacement Parts List</h3>
Diagram Item # Part Description / # Where To Buy
11 Heat Exchanger Sub Assembly, 3 Cell – 2821300 Sears Parts Direct
21 Primary Limit Switch 160 Degrees – 1370908 Amazon
31 3 Burner Manifold – B2526001 Sears Parts Direct
41 White Rogers Gas Valve H.S.I. – B1282614 Amazon
51 3 Cell Attachment Gasket – B2832600 Sears Parts Direct
61 Secondary Heat Exchanger Coil 14″ – 2864604S Sears Parts Direct
71 2 Cell Lower Inner Front – 2830100 * N/A
81 Flue Collector Box 14″ – B2810004 / 2820004S Sears Parts Direct
NS Coil / Lower Inner Front Gasket – B2832512 Sears Parts Direct
NS Flue Collector Gasket 14″ – B2832500 Ebay
NS Stack Overtemp Switch – B1370253 Ebay
NS = Not Shown
* = Obsolete

Goodman GMPN060-3 Burner Box Replacement Parts List

Goodman GMPN060-3 Burner Box  Parts Diagram
Diagram Item # Part Description / # Where To Buy
11 Burner Box Side Qty 2 – 2514000 * N/A
21 Burner Box Top 3 Cell - 2513001 * N/A
31 Auxiliary Limit Bracket Qty 4 – 2509503F * N/A
41 Furnace Burner Roll-Out Limit Switch - B1370154 Amazon
51 Flame Sensor – B1172606 Amazon
61 Hot Surface Ignitor – B1401018 Amazon
81 Burner Bracket 3B – 2513501 * N/A
91 Inshot Burner Assembly 3″ N/A
101 Burner Rack 3 Cell – 0121F00157 * N/A
NS #45 Orifice – B2589345 Amazon
NS = Not Shown
* = Obsolete

Goodman GMPN060-3 Control Panel Parts List

<h3>Goodman GMPN060-3 Control Panel Parts List </h3>
Diagram Item # Part Description / # Where To Buy
12 Control Mount Panel – 1815817 * N/A
22 Motor Run Capacitor 10 / 370V – CAP125000370CP Amazon
32 Transformer 120V To 24V, 40VA – 0130M00140 – Replaces B1141605 Ebay
42 HSI Board w/ 9 Pin Connector – B1809913 Ebay
NS = Not Shown
* = Obsolete

Goodman GMPN060-3 Blower Motor Assembly Parts List

Goodman GMPN060-3 Blower Motor Assembly Parts Diagram
Diagram Item # Part Description / # Where To Buy
13 Blower Housing 10 x 6 – 2539305 Sears Parts Direct
23 Blower Block-Off 10 x 6 – 764739 * N/A
33 Direct Drive Blower Motor 1/3 HP – B1340021 Amazon
43 Blower Wheel 10 x 6 – B1368034 / B1368034S Ebay
NS Wire Kit GMPN Direct – 2868509 * N/A
53, 63, 73 Does not pertain to the GMPN040-3. Blower motor and accessories for Goodman GMPN120-5 Only N/A

GMPN060-3 Air Filters & Accessories

AIRx Filters Allergy 16x25x1 Air Filter MERV 11 AC Furnace Pleated Air Filter Replacement Box of 6, Made in the USA
Side Air Install Filters 18 x 25
Bottom Install Air Filters 14 x 25
Bottom Install Air Filters 14 x 25
Natural Gas To Propane Conversion Kit LMP01
Natural Gas To Propane Conversion Kit LMP01

Goodman GMPN060-3 Manuals

Goodman GMPN060-3 Manuals
Manuals
Goodman GMPN060-3 Service Instructions Manual
Goodman GMPN060-3 Repair Parts Guide
Goodman GMPN060-3 Installation & Operating Instructions Manual

GMPN060-3 Troubleshooting Tips & Videos
WARNING: These troubleshooting steps can be taken to try and identify any problems associated with your furnace. However, if you do not feel comfortable servicing your furnace , you should call a service technician. Always turn off the power at the panel before reaching into the unit. This info is meant for certified servicemen and is for informational purposes only. 

Products should be serviced only by a qualified service technician who is familiar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testing instruments and the appropriate service manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE SERVICE MANUAL BEFORE BEGINNING REPAIRS.
GMPN060-3 Service Status Lights
Additionally, check the Service Instructions Manual above beginning on page 38 to view troubleshooting instructions on a certain part or parts. 
Goodman furnace 4 blink code model gmpn060-3 limit switch faulty
Goodman gmpn 060-3 blower motor replacement
The Legal:

Contact Us

Copyright Notice

Privacy Policy
​

Terms & Conditions